Install Image-Master 7 Post Installation
Notes
If you elect to assign the new 64-bit workstations
their own Image-Master machine ID that is different from the
existing Ids in use, you must edit the IMASTER.INI once in notepad
after the installation has finished, copy the existing DefaultDBF=
line from an existing [StationA] group, and paste it under the
corresponding [Station...] section for the new machine ID selected
during installation.
Post Installation Notes for Special
Situations
-
Scanning Stations running Windows NT,
2000,2003,2008,XP,Vista or Win 7 using the TWAIN interface
It is possible that restricted rights users will be
unable to scan from these workstations until the administrator has
granted increased privileges to the (\WINNT\TEMP or \WINDOWS\TEMP)
and the (\WINNT\TWAIN32 or \WINDOWS\TWAIN32 or \WINDOWS\TWAIN_32)
directories. If restricted rights users cannot scan, try to scan as
the administrator. If the administrator can scan, change the
security settings of the two directories indicated above for all
users.
-
Color Image Viewing Support in FullView
Professional
FullView
Professional now supports 24-bit color JPEGs and JPEG encoded
TIFF files. Print to
Image-Master, File to
Image-Master, and Kofax Interface Scanning all
support the creation of full-color documents. In order to display
color images from within FullView, the Kofax Runtime Version
3.65.60 or later must be installed on the workstation. Image-Master
5 comes with Version 3.75 of the Kofax Runtime which is suitable
for non-scanning, TWAIN scanning, and Adrenaline 650i workstations
ONLY. If the workstation uses a Kofax Adrenaline 850s, 850v, 1700s,
or any KF series card to scan, do not follow this procedure.
Instead, download and install the most current runtime for the
appropriate model interface card from www.Kofax.com. To accomplish
the Kofax Runtime upgrade on workstations needing this feature, use
either of the following methods:
-
Changing the
Idle
Wait Time for IMPTI7
The default time for closure of all idling IMPTI
processes and modules on the network is one hour. You can reduce
the idle wait time for IMPTI7 by making an edit in IMASTER.INI.
To change the default time for closure of idling
processes, edit IMASTER.INI as follows:
A. Open the F:\IMaster\IMASTER.INI file with a text
editor.
B. Navigate to the bottom of your Section Group and insert the
following:
IdleTimeout= {time to wait in minutes}
Example of a 5 Minute Idle Timeout Setting
IdleTimeout=5 would shutdown IMPTI7 five minutes
after it was finished.
Related Topics
Installing and
Upgrading Image-Master Introduction
|